@misc{Kaul_Matresh_Response, author={Kaul, Matresh and Nallasivan, K.}, howpublished={online}, publisher={Zielona Góra: Oficyna Wydawnicza Uniwersytetu Zielonogórskiego}, language={eng}, abstract={During previous earthquakes around the world, it was discovered that elevated water tanks were severely damaged or collapsed. As a result, structural engineers are concerned about the analysis of these structures to gain a better understanding of the effects of seismic loads on elevated water tanks. In the current study, E-Tabs software, which is based on finite elements, is used to model various shapes of elevated water tanks along with various staging patterns.}, abstract={The higher stiffness of the supports in cross staging tanks makes them better than normal staging tanks, according to the results of the analysis. Furthermore, circular tanks perform better than other tank shapes when subjected to seismic loads. The study looks at water tanks subjected to static seismic loads. More research is needed to determine the analysis results for the dynamic seismic loads applied to the structure. All the analysis results are derived from the software's tank analysis results.}, type={artykuł}, title={Response of Elevated Water Tanks Subjected to Lateral Loads}, keywords={water tanks, raising tanks, seismic load, equivalent static method, zbiorniki na wodę, podwyższanie zbiorników, obciążenie sejsmiczne, równoważna metoda statyczna, E-Tabs model}, }