composite beam ; beam ; cold-formed steel ; channel connectors ; load ; belka stalowo-betonowa ; kompozyt ; złącze kanałowe ; obciążenia
Abstract:Steel-concrete composite structures are widely used in the current construction of bridges and multi-storey buildings. The effect of shear connectors in a cold-formed steel-composite beam was studied under flexure. The number of channel connectors in the specimen was varied and the same was compared with a specimen without shear connectors. The performance and failure of cold-formed steel-composite beams were then studied. ; The presence of shear connectors in the tension zone prevents the formation of cracks which are the major cause of failure in a beam subjected to bending. The load carrying capacity is greater in a composite beam and an increase in the number of channel connectors from one to five increases the load-carrying capacity by 60% as compared to a specimen without a connector. A composite beam with five connectors is more ductile, with a ductility factor of 14. The Composite beams were also analysed using the finite element software ANSYS and were found to have good agreement with the experimental results.
Description:tytuł dodatkowy: Prace z Inżynierii Lądowej i Środowiska
Publisher:Zielona Góra: Oficyna Wydawnicza Uniwersytetu Zielonogórskiego
Date: Resource Type: Format: DOI: Pages: Source:Civil and Environmental Engineering Reports (CEER), no 29, vol. 3
Language: License CC BY-NC-ND 3.0: Rights: