@misc{Sobolewski_Łukasz_Comparison, author={Sobolewski, Łukasz}, howpublished={online}, publisher={Zielona Góra: Uniwersytet Zielonogórski, Instytut Metrologii, Elektroniki i Informatyki}, language={eng}, abstract={The article presents research results on predicting the deviations for two different timescales, UTC(PL) and UTC(NPL) by means of GMDH type Neural Network. UTC(PL) timescale was realized by commercial caesium atomic clock. The UTC(NPL) timescale, on the other hand, is based on an active hydrogen maser, additionally supervised by the primary frequency standard in the form of a caesium fountain.}, abstract={Input data has been prepared in the form of two time series. Better quality of prediction has been obtained for UTC(NPL) timescale. Obtained values of predictions differ from the deviations published by the BIPM at the same day of prediction by max +- 3.6 ns for two time series.}, type={rozdział w książce}, title={Comparison of quality of UTC(PL) and UTC(NPL) scales prediction by means of GMDH Neural Network = Porównanie jakości prognozowania skal UTC(PL) i UTC(NPL) z zastosowaniem sieci neuronowej GMDH}, keywords={jakość prognozowania, UTC(PL), UTC(NPL), sieci neuronowe}, }