A water for injection system supplies chilled sterile water as a solvent for pharmaceutical products. There are ultimate requirements for the quality of the sterile water, and the consequence of a fault in temperature or in flow control within the process may cause a loss of one or more batches of the production. Early diagnosis of faults is hence of considerable interest for this process. ; This study investigates the properties of multiple matchings with respect to isolability, and it suggests to explore the topologies of multiple use-modes for the process and to employ active techniques for fault isolation to enhance structural isolability of faults. The suggested methods are validated on a high-fidelity simulation of the process.
Zielona Góra: Uniwersytet Zielonogórski
AMCS, volume 18, number 4 (2008) ; click here to follow the link
Biblioteka Uniwersytetu Zielonogórskiego
Jul 14, 2025
Apr 8, 2024
109
https://zbc.uz.zgora.pl/repozytorium/publication/88517
| Edition name | Date |
|---|---|
| Fault diagnosis of a water for injection system using enhanced structural isolation | Jul 14, 2025 |
Kościelny, Jan Maciej Syfert, Michał Rostek, Kornel Sztyber, Anna Korbicz, Józef (1951- ) - red. Uciński, Dariusz - red.
Pröll, Sebastian Lunze, Jan Jarmolowitz, Fabian Puig, Vicenç - ed. Sauter, Dominique - ed. Aubrun, Christophe - ed. Schulte, Horst - ed.
Fang, Shaoji Blanke, Mogens Korbicz, Józef (1951- ) - red. Uciński, Dariusz - red.
Tatara, Marek S. Kowalczuk, Zdzisław (1953- ) Korbicz, Józef (1951- ) - red. Uciński, Dariusz - red.
Calado, Joao M.F. Sá da Costa, Jose M.G. Korbicz, Józef (1951- ) - red. Patton, Ronald J. - red.
Ducard, Guillaume J.J. Simani, Silvio - ed. Castaldi, Paolo - ed.
Kościelny, Jan Maciej Bartyś, Michał Korbicz, Józef (1951- ) - red. Uciński, Dariusz - red.
Witczak, Marcin Pazera, Marcin Majdzik, Paweł Matysiak, Ryszard Korbicz, Józef (1951- ) - red. Uciński, Dariusz - red.